Customer’s request

Extraction of fumes produced during the application of mastic sealants in the manufacturing context of automotive components. The goal is the protection of the operators with a safety system.

Solution

Centralized extraction plants for capturing of the steams directly on the machinery and optical units production lines.

Capturing is carried out directly from the pumps area and from the application area managed by robots.

Design

Sizing of the correct speeds of the air both during capturing of the pollutants and in crossing in the extraction ducts with subsequent calculation of total load losses depending on the path of the piping

Selection of a simple extraction centrifugal fan is by considering the overall plant capacity and the load losses of the connected systems.

Extracting ducts and hoods in galvanized steel metal sheet

Expulsion to outside

Photogallery


Associate systems


Ask a quotation or contact us


Company (*)
Name
Last name (*)
City (*)
District

Country

Phone
E-mail (*)
Message (*)
security code (*)
captcha

Fields marked with an asterisk (*) are required to send the message

privacy (*)

As provided for by Legislative decree 196/2003 on the protection of personal data please note that the data supplied by filling in the form will be collected by Gamma Impianti Srl using electronic and/or computerised means. Data supplied will be used only for market research purposes. You may, at any time, exercise your rights provided for by art. 7 of Legislative Decree 196/2003. By clicking on the Send button I declare that I have read this notice and that I give my consent to process my personal data on the basis of the above notice.

I accept